This list contains all significant changes at the components of the program between 09/23/2007 and 05/30/2008
| Version | Module | Details |
|---|---|---|
| 8.6.6 (05/30/2008) |
1092 | Iteration with reduced allowable goals enhanced |
| Version 2007 updated | ||
| Pressure-temperature ratings added | 12516A | Iteration with reduced allowable goals enhanced |
| 12516B | Iteration with reduced allowable goals enhanced | |
| 1514 | Iteration with reduced allowable goals enhanced | |
| 1514N | Iteration with reduced allowable goals enhanced | |
| ANSI | Wall thickness corrected | |
| B5 | CAD functionality | |
| B51 | CAD Functions added | |
| B9 | Edition Nov.2007 added | |
| EF01 | Iteration with reduced allowable goals enhanced | |
| EF02 | Iteration with reduced allowable goals enhanced | |
| EFLA | Iteration with reduced allowable goals enhanced | |
| SFLA | Iteration with reduced allowable goals enhanced | |
| SPIE | CAD added | |
| UG32 | Available reinforcement width of the crown region added | |
| UG34 | Factor 2 for the required reinforcement area A35 corrected | |
| VFLA | Iteration with reduced allowable goals enhanced | |
| VFLN | Iteration with reduced allowable goals enhanced | |
| ZIEH | Installation bolt torque acc. VDI 2230 implemented | |
| Construction allowance c5 added | ||
| 8.6.5 (03/28/2008) |
3840 | Gasket Database activation in conection with AD B7 fixed | ANSI | Wall thickness standard added |
| ATLAS System | Using the LV System as Excel server, an error occured in the WMS. Error fixed | |
| B51 | Expansion coefficient changes to microns | |
| Feezing | Corrections for English version | |
| FEM | Material data base connection fixed | |
| HPR | Version Nov. 2007 | |
| IGEL | Field boundaries extended for inline nozzles | |
| Unit Nm changed to N | ||
| Material | Window placed in foreground | |
| Gasket Database activation in conection with AD B7 fixed | ||
| S30 | Version Nov. 2007 | |
| 8.6.4 (01/18/2008) |
12516C | e0 replaced by required wall thickness ec in Eq. (57) | AFL | Edition 2007 |
| APY | Edition 2007 | |
| ATB | Edition 2007 | |
| ATLAS System | Treeview bug, Group owner fixed | |
| ASCII value bug fixed | ||
| Command button color fixed to windows styles | ||
| Dynamical super iteration integrated | ||
| Recalculation options before printing are now identical with original calculation options. | ||
| Treeview bug fixed | ||
| Print menue activation via remote request | ||
| Treeview look and feel changed | ||
| B0 | Min pp = Fp*pzul acc. HP30 section 4.10.1 added | |
| B3 | Negativ SQR bug fixed | |
| B51 | Pmax calculation enabled | |
| Edition 08.2007 added | ||
| B9 | Wall thickness sA acc. 4.3.3. corrected for reduced reinforcement width | |
| EJMA | Edition 1998 corrected as 2005 | |
| EN09 | Angle calculation for multiple nozzles added | |
| ER08 | Section 8.3.6 for branch with reinforcing ribs added | |
| FEM | Schreibfehler auf der Maske behogen | |
| Global loadchange added | ||
| IGEL | local stress calculation and NozzleSpec added | |
| Material | Gasket factors according manufacturer manuals addes | |
| UG27 | Edition 2007 | |
| UG28 | Edition 2007 | |
| UG29 | Edition 2007 | |
| UG32 | Edition 2007 | |
| UG33 | Edition 2007 | |
| UG34 | Edition 2007 | |
| UG37 | Edition 2007 | |
| UHXa | Edition 2007 | |
| UHXb | Edition 2007 | |
| UHXC | Edition 2007 | |
| Zusa | Recursion removed | |
| 8.6.2 (10/08/2007) |
12516A | Type mismatch corrected | 12516B | Loadcase test added |
| 301 | Endless loop after module copying removed | |
| ATLAS System | Bug fix for suggestion values , edit values | |
| Mask problems with Excel fixed | ||
| B0 | Issue date changed | |
| B51 | Loading older version files enabled | |
| B7 | Variables for bolt diameter equations corrected | |
| ER07 | Flat heads added | |
| Excel-Addin | Recursivity while shutdown removed | |
| Mask problems with Excel fixed | ||
| Material | AD-S6 time dependent material properties added | |
| EN10269:2006 implemented | ||
| EN13480 ergänzt | ||